Suitable for soil and vent systems, Ubbink's OFT/1F Flat Roof Vent/Terminal is the perfect option for flat roof extraction. It is also usable for natural (passive) or mechanical ventilation installations. Ideal for a felt roof covering, providing a large free vent area wit... Read More
SUPER rewards Earn points and save £££ on our SUPERSTORES
Find out morePay in 3 interest-free payments of £0.00
Learn moreSuitable for soil and vent systems, Ubbink's OFT/1F Flat Roof Vent/Terminal is the perfect option for flat roof extraction. It is also usable for natural (passive) or mechanical ventilation installations. Ideal for a felt roof covering, providing a large free vent area with a low Pascal resistance figure.
This vent/terminal is available with varying pipe diameters to allow termination through a flat roof to ducting and comes with an aluminium flange. Additionally, the Ubbink OFT/1 has a stack cap to fix mechanically to ensure the system is more secure when installed in extreme weather. If needed, this part is removable for servicing purposes.
Please note:
There are no product downloads to show.
Question:
Can the aluminium collar be angled by hand slightly @ I have an 8-10 degree pitch in a felt roof.
Answer:
The OFT/1F is designed for flat roofs, and we can’t confirm that its aluminium collar is intended to be angled by hand. A small adjustment may be possible, but avoid forcing it or creating creases or damage that could affect the weatherproofing. The vent should remain as close to vertical as possible, with particular care taken to seal the flange correctly to the felt. For a definitive recommendation for an 8–10° pitch, please check with the supplier or our technical team.
Question:
Would this work on a low pitch roof of approximately 15 degrees
Answer:
The Ubbink OFT/1F Flat Roof Vent/Terminal is designed specifically for flat roofs, so it may not be suitable for your low pitch roof of 15 degrees. However, this can also depend on other factors like the specific installation and roof materials. It would be best to consult with a professional installer or our technical team for the most accurate recommendation based on your specific circumstances.
Question:
this will be installed on a flat grass roof; can it be raised as the build up of materials over the OSB roof is about 100mm and I would like the vent to be higher?
Answer:
Yes, you can raise the Ubbink OFT/1F Flat Roof Vent/Terminal - 110mm on your flat grass roof. This is generally done by raising the pipework below the vent or using a purpose-designed extension piece, rather than extending the vent terminal itself. Please ensure that any modifications maintain the integrity of the vent's functionality and comply with any relevant building regulations. If you need more specific advice on how to achieve this, we recommend consulting with a roofing specialist or a professional installer.
Question:
Hi i am looking to vent a 150mm cooker extractor fan through a flat roof, will the 110mm Ubbink OFT/1F Flat Roof Vent/Terminal and a reducer do the job, thanks
Answer:
While the Ubbink OFT/1F Flat Roof Vent/Terminal - 110mm is designed to provide effective ventilation, it might not be the best fit for your needs. This is because the pipe diameter of this vent is 110mm, which is smaller than the 150mm requirement of your cooker extractor fan. Even with a reducer, it could potentially compromise the efficiency of the fan due to the smaller vent size. However, there is a larger version of this vent, the Ubbink OFT/1F Flat Roof Vent/Terminal - 160mm, which might be a better match for your cooker extractor fan. This vent has a pipe diameter of 160mm, closer to your requirement. You can view the Ubbink OFT/1F Flat Roof Vent/Terminal - 160mm on our website by clicking here. Before making a decision, I recommend consulting with a professional installer to ensure the vent will work effectively with your extractor fan and meet any building regulations.
Question:
Hi I’ve bought 3 of these for my epdm flat roof. Can you tell me what which flashing or witches hat I need to make this waterproof please?
Answer:
To ensure the Ubbink OFT/1F Flat Roof Vent/Terminal is waterproof on your EPDM flat roof, it's crucial that the vent is properly flashed. However, the specific flashing or "witches hat" you need depends on your specific roof setup and the vent product specifications. For this Ubbink OFT/1F Flat Roof Vent/Terminal, it's designed to be compatible with standard roofing materials, so a standard flashing that can accommodate a 110mm pipe should work. However, it's always best to consult with a roofing professional or contractor who is familiar with your specific roofing setup to ensure you get the appropriate flashing.
Question:
We are considering this for venting a bathroom fan out to a rubber-covered flat roof. We have a rubber flange that looks like a witches hat which you cut down to the correct size to allow the vent to pass through it. Do we stick this down over the metal flange? If so, what are the dimensions of the metal flange so I can check our rubber "witches hat" flange will cover it?
Answer:
Yes — your rubber “witches‑hat” EPDM flange does get bonded over the metal flange on the Ubbink OFT‑1F.
The metal flange on the 110 mm model is 330 mm in diameter, so your EPDM boot must comfortably cover at least that area
Question:
Hi. Is this suitable for a 100mm ducting from a shower extractor?
Answer:
100%
Question:
I would be installing in a felt/bitumen roof how is it fixed?
Answer:
You would need to ensure that the felt/bitumen is covering the flange of the vent and that it is fully watertight.
Question:
Can use this product for an extraction hood go through with GRP flat foof?
Answer:
Yes you can
Question:
How do I connect the roof vent 110mm pipe to 125mm ducting pipe?
Answer:
I will email you the correct one
Question:
Does this come with the flange for fixing on a felt roof?
Answer:
The Ubbink OFT/1 range is available in five different flange types for different roof coverings, Asphalt, Felt, EPDM, Bitumen and PVC - you just need to state what one you need in the notes
Question:
Is this suitable for GRP roof? If so, please forward installation manual/ instructions. T
Answer:
Yes this can be used on a GRP Roof
Question:
I have a flat roof (GRP) with 200mm joists. Can I cut the 600mm pipe down to fit?
Answer:
Yes you can cut the lower pipe to suit your needs
Question:
Would this be suitable for a kitchen extractor to vent through a felt garage roof?
Answer:
100% yes
Question:
Would this vent be suitable for bathroom extraction?
Answer:
Yes 100%
Question:
Can this be used in a GRP flat roof?
Answer:
Yes it can
Question:
Hi I'd like to buy Ubbink OFT/1F Flat Roof Vent/Terminal - 160mm but in pvc flange option but there is no option to choose so, can you please help with this. Thanks
Answer:
Please call in and speak with one of the team as there may be alternative ideas
Question:
Have you got this for a bitumen felt application?
Answer:
This item is provided with a flangle suitable for insyallation with Bitumen Felt.
Question:
How do you waterproof in grp roof. What do you deal with to make waterproof.
Answer:
Part of installation will be dressing GRP back over the flange to make this waterproof. We would recommend getting a Roofer to do this job as GRP is a more specialist product.